RESPIRATORY

 

Defender Cartridge

Particulate Filters  

FF2 Pre Filter

RN54001

Full Face Mask

RN550030M & RN550030L

Half mask Respirator

RN76008A 

Full Face ( Silicone)

RN770030M & RN770030L

Half Mask Silicone

RN75002

Cartridge A1

RN75008 

Cartridge P3

RN750089 - DEFENDER P3  (75SCP100)

Combination Cartridge

Half Mask Double

RP193

Half Mask Single

SH9100

FF1

SH9250

FF2

SH9250CV

FF2 Carbon Valve

SH9250V

FF2 Valve

SH9260CV

FF2 Carbon Adjustable

SH9360V

FF3

  

RN750089 - DEFENDER P3  (75SCP100)

RN750089 - DEFENDER P3  (75SCP100)    

Organic & Inorganic Gases & Vapours, Acid Gases & Particulates-

 

Defender Multi purpose cartridge for Organic Vapours, Chlorine, Hydrogen Chloride, Sulphur Dioxide, Hydrogen Sulphide (Escape), Hydrogen Fluoride, Chlorine Dioxide, Ammonia, Methylamine and Formaldehyde with P3 Efficiency Particulate Filter. (99.97% Minimum Filter Efficiency)

Precautions:

Not to be used in areas that are Oxygen deficient i.e. where Oxygen is below 19%.

Not to be used where the contaminant is IDLH.

Only to be used with North Safety Products approved Respirator

Back To Respiratory

Download Specification Data

 

 

Half Mask Double (RP194)

 

Product:                 Twin Half Mask                                                                                     

Neoprene rubber half mask with 2 direct thread cartridge holders. 

Comfortable low breathing resistance and easy fit headgear.  Wide assortment of cartridges for various applications.

Physical Properties:             Non allergenic moulded soft rubber. Elastic type head harness.  
                                                Quick release buckle on the elastic neck strap.                                                                                                                              

Standards:                            EN140                                    

Uses:                                      Can be used with the 7500 series filters, or as a Face piece with compressed airline apparatus CF2000 Plus.                                                                                                                                                      

                                                Half mask Respirator approved for use against                                                                                       

                                                Chlorine            
                                                Non-Oil Particulates   
                                                Mercury Vapour 
                                               Hydrogen Chloride      
                                               Ammonia                        
                                              Sulphur Dioxide    
                                              Methylamine     
                                              Chlorine Dioxide     
                                             Organic Vapour                                      

Cartridges:                                                                                           

                                     RN75000 B1                           (Inorganic gases & vapours)                  
                                     RN65006A P1                         (Dust Particles)                                                                                                       
                                     RN75006 P1                           (Dust Particles)                                   
                                     RN75007 P2                           (Dust Particles)                       
                                     RN75008 P3                           (Dust Particles)                       
                                     RN750080 B1P3                    (Inorganic gases & vapours & particles
                                     RN750081 A1P3                    (Organic Gases & Vapours & particles)      
                                     RN750083 A1B1E1P3            (Organic & Inorganic Gases & Vapours, Acid gases & particles)                 
                                     RN75004 K1P3                       (Ammonia & Organic ammonia derivatives & particles)           
                                     RN75001 A1                           (Organic Gases & Vapours with boiling point >65 Degrees C)       
                                     RN75002 A1E1                       (Organic & Acid Gases & Vapours)                                                                        
                                     RN75002 P1A1E1P1              (Organic & Acid Gases & Vapour, Sulphur Dioxide & Particles)                   
                                     RN75003 A1B1E1                  (Organic/Inorganic gases & vapours, Acid Gases & So2)                                      
                                     RN75003P2A1B1E1P2          (Dust Particles, Organic/Inorganic Gases, Acid and So2)                          
                                     RN75004K1                            (Ammonia & Organic ammonia derivatives)                                                            
                                    RN75001P2A1P2                    (Dust Particles & Organic Gases and vapours)                                                               

                Particle filter classes 1, 2 and 3 according to different retention capacity  

Pre-Filters:

                                RN75006A                              (Dust/Mist P1)

                                RN750010                               (Spray paint / Mists P2)

                                RN750023                               (Pesticide (P2)

 

Precautions:             Not to be used in areas that are Oxygen deficient i.e. where Oxygen is below 19%.

                        Not to be used where the contaminant is IDLH.

                                                Only to be used with North Safety Products approved 7500 series screw in cartridges.

                                                Only to be used with the applicable cartridges to protect from the particular hazard.

                                                Not to be worn with facial hair, i.e. no beards or moustaches.

Back To Respiratory

Download Specification Data

 

Half Mask Single (RP193)

RP193

 

Product:                 Single Half Mask

Neoprene rubber half mask with single direct thread cartridge holder.  Comfortable low breathing resistance and easy fit headgear.  Wide assortment of cartridges for various applications.

Physical Properties:             Non allergenic moulded soft rubber. Elastic type head harness.                                             
                                                Quick release buckle on the elastic neck strap.                              

Standards:                            EN140                                    

Uses:                                      Can be used with the non combination 7500 series filters.                                                                                                                                       

                                                Half mask Respirator approved for use against                                                                                       

                                                Chlorine   
                                                Non-Oil Particulates                                                                
                                                Mercury Vapour                     
                                                Hydrogen Chloride                                                                 
                                                Ammonia                                 
                                                Sulphur Dioxide                                                                      
                                                Methylamine                                           
                                               Chlorine Dioxide                                                                     
                                                Organic Vapour                                      

Cartridges:

                                RN65006A P1                         (Dust Particles)                                                                                                      
                                RN75006 P1                           (Dust Particles)                                                                                                       
                                RN75008 P3                           (Dust Particles)                                                       
                                RN75001 A1                           (Organic Gases & Vapours with boiling point >65 Degrees C)                
                                RN75004K1                            (Ammonia & Organic ammonia derivatives)            

                 Particle filter classes 1, 2 and 3 according to different retention capacity  

Pre-Filters:                                                                                            

                                RN75006A                              (Dust/Mist P1)                                                         

                                RN750010                               (Spray paint / Mists P2)                                                          

                                RN750023                               (Pesticide (P2)

 

Precautions:              Not to be used in areas that are Oxygen deficient i.e. where Oxygen is below 19%.

                         Not to be used where the contaminant is IDLH.

                                                Only to be used with North Safety Products approved 7500 series screw in cartridges.

                                                Only to be used with the applicable cartridges to protect from the particular hazard.

                                                Not to be used with combination cartridges.

                                                Not to be worn with facial hair, i.e. no beards or moustaches.

Back To Respiratory

Download Specification Data

 

 

FF1

SH9100

Product:                 FFP1SL Dust/Mist Respirator            

Physical Properties:            

A low profile mask offers a better fit with glasses and goggle.

A soft inner lining offers more comfort and less irritation.  

Low breathing resistance increases workers acceptance.

Smooth, pre stretched head straps offer a good fit and comfort over the head and neck.                                 

Contoured adjustable nosepiece offers maximum performance.      

Standards:               CE EN149 FFP1S  SABS

                                                SABS Homologation No: 33723 Approval No AZ2003/45   

Uses:                                     

For use against fine respirable non-toxic dust and fibres.

For use up to 4 x OEL or 4 x APF.

Precautions:                         

Do not use in spray-paint operations.

Do not use in sandblasting operations.

Do not use for protection against asbestos.

Do not use when concentrations of contaminant are unknown or immediately dangerous to life or health.

Not to be worn with facial hair, i.e. no beards or moustaches.

Back To Respiratory

Download Specification Data

 

 

FF2

SH9250

                                                                                                                                               

Product:                 FFP2SL Dust/Mist Respirator            

Physical Properties:            

A low profile mask offers a better fit with glasses and goggle.

A soft inner lining offers more comfort and less irritation.  

Low breathing resistance increases workers acceptance.

Smooth, pre stretched head straps offer a good fit and comfort over the head and neck.                                 

Contoured adjustable nosepiece offers maximum performance.

                                                       

Standards:               CE EN149 FFP2S SABS     

SABS Homologation No: 33723 Approval No AZ2003/47   

Uses:                   For use against low to average -toxic dust, fumes and aqueous mist.
For use up to 12x OEL or 10 x APF.

Precautions:                         

Do not use in spray-paint operations.

Do not use when concentrations of contaminant are unknown or immediately dangerous to life or health.

Not to be worn with facial hair, i.e. no beards or moustaches.

Back To Respiratory

Download Specification Data

 

FF2 CV

                                               SH9250CV                                                    

Product:                 FFP2SL Active Carbon Respirator with Valve 

                                                               

Physical Properties:            

The exhalation valve offers lower breathing resistance for easier breathing which increases workers acceptance.

Activated carbon offers the additional protection against organic gas at nuisance levels.

A low profile mask offers a better fit with glasses and goggle.

A soft inner lining offers more comfort and less irritation.          

Smooth, pre stretched head straps offer a good fit and comfort over the head and neck.                                         

Contoured adjustable nosepiece offers maximum performance.

                                               

Standards:              CE EN149 FFP2S  SABS SABS Homologation No: 33723 Approval No AZ2003/49

                                                               

Uses:                                     

For use against low to average -toxic dust, fumes and aqueous mist.

For use up to 12x OEL or 10 x APF.      

For use against organic gases at nuisance levels.                  

Precautions:                          Do not use when concentrations of contaminant are unknown or immediately dangerous to life or health.

                                                Not to be worn with facial hair, i.e. no beards or moustaches

Back To Respiratory

Download Specification Data

 

FF2 V

SH9250V

 

Product:                 FFP2SL Dust/Mist Respirator with Valve

Physical Properties:            

A low profile mask offers a better fit with glasses and goggle.

A soft inner lining offers more comfort and less irritation.  

Low breathing resistance increases workers acceptance.

Exhalation valve offers comfort and durability.

Smooth, pre stretched head straps offer a good fit and comfort over the head and neck.                                 

Contoured adjustable nosepiece offers maximum performance.      

Standards:                CE EN149 FFP2S SABS     

SABS Homologation No: 33723 Approval No AZ2003/39   

Uses:                   For use against low to average -toxic dust, fumes and aqueous mist.
For use up to 12x OEL or 10 x APF.

Precautions:                         

Do not use in spray-paint operations.

Do not use when concentrations of contaminant are unknown or immediately dangerous to life or health.

Not to be worn with facial hair, i.e. no beards or moustaches.

Back To Respiratory

Download To Specification Data

 

FF2 CV ADJ

SH9260CV   

 

Product:                  FFP2SL Active Carbon Respirator with Valve

                         (FFP2SL Welding Mask with Adjustable Head Straps)              

Physical Properties:      

The exhalation valve offers lower breathing resistance for easier breathing which increases workers acceptance.

Activated carbon offers the additional protection against organic gas at nuisance levels.

A low profile mask offers a better fit with glasses and goggle.

A soft inner lining offers more comfort and less irritation.          

Smooth, pre stretched head straps offer a good fit and comfort over the head and neck.                                  

Contoured adjustable nosepiece offers maximum performance.

                                               

Standards:            CE EN149 FFP2S SABS                                                                        
                     
SABS Homologation No: 33723 Approval No AZ2003/48

                                                               

Uses:                                    

For use against low to average -toxic dust, fumes and aqueous mist.

For use up to 12x OEL or 10 x APF.               

For use against organic gases at nuisance levels.

For use in Welding Applications.

Precautions:                     

Do not use when concentrations of contaminant are unknown or immediately dangerous to life or health.

Not to be worn with facial hair, i.e. no beards or moustaches.

Back To Respiratory

Download Specification Data

 

FF3

SH9360V

 

Product:                  FFP3 Premium Respirator with Valve.               

Physical Properties:            

The exhalation valve offers lower breathing resistance for easier breathing which increases workers acceptance.

Activated carbon offers the additional protection against organic gas at nuisance levels.

A low profile mask offers a better fit with glasses and goggle.

A soft inner lining offers more comfort and less irritation.          

Smooth, pre stretched head straps offer a good fit and comfort over the head and neck.                                         

Contoured adjustable nosepiece offers maximum performance.

Standards:               CE EN149 FFP3S

                                                SABS Homologation No: 33723 Approval No AZ2003/50   

Uses:                                     

For use against average to high -toxic dust, fumes and aqueous mist.

For use up to 50x OEL 0r 20 x APF.      

Precautions:                         

Do not use in spray painting operations.

Do not use when concentrations of contaminant are unknown or immediately dangerous to life or health.

Not to be worn with facial hair, i.e. no beards or moustaches.

 

Back To Respiratory

Download Specification Data